Impression Plus Series
®
Metered Water Softeners
Installation Instructions & Owner’s Manual
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Impression Plus Series

Impression Plus Series®Metered Water SoftenersInstallation Instructions & Owner’s Manual

Page 2 - TABLE OF CONTENTS

105. ERROR MESSAGE: If the word “ERROR” and a number arealternately flashing on the display record the number and contactthe dealer for help. This ind

Page 3 - BYPASS VALVE:

START-UP INSTRUCTIONS:11• After installation is complete, rotate bypass handles to bypass mode (see Fig.2 on page 4).• Turn on water and check for lea

Page 4

12Timer does not display time of dayA. transformer unplugged A. reconnect transformerB. no power at outlet B. repair or use working outletC. defective

Page 5 - INSTALLATION:

13PROBLEM CAUSE CORRECTION Valve does not regenerateautomaticallywhen REGENbutton is pressedA. transformer unplugged A. connect transformer and PC boa

Page 6

14REPLACEMENT PARTS:2713546FRONT COVER AND DRIVE ASSEMBLYItem No. Part No. Description Qty.1 CV3540P-DUPURE DuPure Impression Plus®cover 12 CV3107-1 M

Page 7 - PROGRAMMING PROCEDURES:

6810117 97 12423511314NOTE: For Impression Plus® Models only. Not available on 1¼ " valve.15REPLACEMENT PARTS:PISTON ASSEMBLYItem No. Part No. D

Page 8

16REPLACEMENT PARTS:BYPASS VALVEItem No. Part No. Description Qty.1 CV3151 Nut, 1" quick connect 22 CV3150 Split ring 23 CV3105 O-ring 215 24 CV3

Page 9 - BATTERY REPLACEMENT

17INJECTOR ASSEMBLIESItem No. Part No. Description Qty.1 CV3176 Injector cap 12 CV3152 O-ring 135 13 CV3177-01 Injector screen 14 CV3010-1Z Injector a

Page 10

18REPLACEMENT PARTS:DRAIN LINE ASSEMBLY 3/4"Item No. Part No. Description Qty.1 CH4615 Elbow locking clip 12 CPKP10TS8-BULK Optional insert, 5/8&

Page 11 - START-UP INSTRUCTIONS:

19WATER METER & METER PLUGItem No. Part No. Description Qty.1 CV3151 Nut, 1" QC 12 CV3003 Meter assembly, includes items 3 & 4 13 CV3118-

Page 12 - TROUBLESHOOTING GUIDE:

TABLE OF CONTENTSPreinstallation Instructions for Dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Bypass Valve . . . . . . . . . . .

Page 13 - PROBLEM CAUSE CORRECTION

20 REPLACEMENT PARTS:BRINE TANK ASSEMBLYItem No. Part No. Description Qty.1CG2195-14 15" x 17" DuPure brine tank cover 1CG2189 Round brine

Page 14 - REPLACEMENT PARTS:

21REPLACEMENT PARTS:132See opposite page for safety float system parts.CABINET BRINE TANK ASSEMBLYItem No. Part No. Description Qty.1 CG2197-01 Salt a

Page 15

1" PVC MALE NPT ELBOWItem No.Part No. Description Qty.CV3007 1" PVC male NPT elbow assembly 21 CV3151 Nut, 1" quick connect 22 CV3150 S

Page 16

231-1/4" & 1-1/2" PVC SOLVENTItem No.Part No. Description Qty.CV3007-07 1-1/4" & 1-1/2" PVC solvent assembly 21 CV3151 Nut

Page 17

11321 Windfern Road • Houston, TX 77064Phone: 281-890-7900 • Toll-free: 1-877-534-5837MANUAL REGENERATIONNOTE: For softeners,if brine tank does no

Page 18

PREINSTALLATION INSTRUCTIONS FOR DEALERS:BYPASS VALVE:3The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt do

Page 19

41. NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flowindicated by the engraved arrows on the control valve. Wate

Page 20

5GENERAL INSTALLATION & SERVICE WARNINGSThe control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There

Page 21

66. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve beforebeginning plumbing. Make provisions to bypass outside hydran

Page 22

7Time of day should only need to be set after extended power outages or when daylight saving time beginsor ends. If an extended power outage occurs, t

Page 23 - SPECIFICATIONS:

8STEP 4 – REGENERATION HOUR: The manufacturer has factory set 2:00 A.M. as the default. Thisis the hour of day for regeneration and can be reset by us

Page 24 - QUICK REFERENCE GUIDE:

3. MANUAL REGENERATION: Sometimes there is a need toregenerate before the control valve calls for it. This may beneeded if a period of heavy water use