Water Right Impression Series Troubleshooting Guide Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
TIME HOUR
SET
2:00
AM
1. Set time of day:
1 2
TIME MINUTES
SET
3
CURRENT DAY
SET
MON
4
PROGRAMMING PROCEDURES:
NOTE: The manufacturer has preset the unit so that the gallons between regenerations will be
automatically calculated after the hardness is entered.
STEP 1 – Press next and + simultaneously for 3 seconds.
STEP 2 HARDNESS: Set the amount of hardness in grains per gallon (default 20) using
the + or buttons. The allowable range is from 1 to 150 in 1 grain increments.
Note: If a resin media is used in the softener, increase the grains per gallon if soluble
iron is present (1ppm = 4 gpg). This display will show “–nA– (not available)”
if “FILTER” is selected or if “AUTO” is not factory set.
Press next to go to step 3. Press regen if you want to exit.
STEP 3 DAYS BETWEEN REGENERATION (DAY OVERRIDE): The manufacturer has factory
set 6 DAYS as the default. This is the maximum number of days between regenerations. If
this is set to “OFF”, regeneration initiation is based solely on gallons used. If any number is
set (allowable range from 1 to 28), a regeneration initiation will be called for on that day
even if a sufficient number of gallons were not used to call for a regeneration.
Set Day Override using + or buttons (6 is recommended):
• set number of days between regeneration (1 to 28); or
• set to “OFF”
NOTE: This valve has the capability of regenerating up to six times in
one day. This can be observed by using the button to toggle below
once a day regeneration (see example to right). These settings are
typically used in twin system configurations or in commercial settings.
Press next to go to step 4. Press regen if you need to return to the
previous step.
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins
or ends. If an extended power outage occurs, the time of day will flash on and off indicating that the time
should be reset.
STEP 1 – Press set clock.
STEP 2CURRENT TIME (HOUR): Set the hour of the day using + or buttons.
AM/PM toggles after 12. Press next to go to step 3.
STEP 3CURRENT TIME (MINUTES): Set the minutes using + or buttons. If it is desired to
back up to the previous step press regen button once. Press next to go to step 4.
STEP 4CURRENT DAY: Set the day of the week using + or buttons. Pressing next will exit
set clock and return to the general operating display (page 10).
REGENS/DAY REGEN
SET
4 / DAY
Example: Indicates unit set
to regen 4 times in one day.
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 27 28

Comments to this Manuals

No comments