GENERAL INSTALLATION & SERVICE WARNINGS
The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments.
There is a small amount of “give” to properly connect the piping, but the water filter is not designed to
support the weight of the plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone lubricant may
be used on black “O” Rings, but is not necessary. Avoid any type of lubricants, including silicone, on red
or clear lip seals.
Do not use pipe dope or other sealants on threads. Teflon
®
tape must be used on the threads of the 1" NPT
inlet and and outlet, the brine line connection at the control valve, and on the threads for the drain line
connection. Teflon
®
tape is not used on the nut connections or caps because “O” Ring seals are used.
The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic Service
Wrench, #CV3193-01. If necessary, pliers can be used to unscrew the nut or cap. Do not use a pipe wrench
to tighten nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer.
SITE REQUIREMENTS
• water pressure – 25-100 psi • current draw is 0.5 amperes
• water temperature – 33-100°F (0.5-37.7°C) • the plug-in transformer is for dry locations only
• electrical – 115/120V, 60Hz uninterrupted outlet
• the tank should be on a firm level surface
1. The distance between the drain and the water filter should be as short as possible.
2. Do not install any water filter with less than 10 feet of piping between its outlet and the inlet of a water
heater. For an IMS or IMB filter, an expansion tank on the outlet side of the system is recommended.
CAUTION: To protect the unit in the event of a hot water heater
backup, the manufacturer recommends the use of an
expansion tank on the outlet side of the unit.
3. Do not locate unit where it or its connections (including the drain and overflow lines) will ever be
subjected to room temperatures under 33° F.